
If you are using nine (9) or more, but less than 16 zones, use programming section 203 (add eight to each numbered zone to get that zone. If you are using less than eight (8) zones use programming section 202 If also enrolling wireless, each wireless device is a zone, with the exception of the key fobs. Since we are using only four (4) zones, we will need to shut off the remaining zones that are not being used. Shutting Off Unused Zones (Program Section 202, 203, or 204) Enter *8-5555-001-01-08-03-05 and at the end of the zone definitions we will hit # to exit. So for our sample kit we would enter everything in order of what we are working with. By default, the keypad will display default zone definitions, ignore these numbers and enter you own. You will not enter zone numbers here, only definitions, and those must be entered in order starting with the first definition. After each two-digit definition, the system will beep and automatically want the definition for the next zone. We will begin adding our Zone Definitions and will use the above chart for reference and we will go straight down the list which begins with Zone Number 01. Adding Zone Definitions (Program Section 001).You will enter the four digit time in 24 hour format (military time) then enter the six digit date example: So if it is 2:30p on October 21, 2008, you would enter 1430 102108, the system will then beep and you would then hit #.
DSC ALARM PANEL PROGRAMMING SOFTWARE CODE
Press *6 to set the time, next enter your master code (1234 is default), then press You will also want to have the ESN of any wireless device also written down next to the proper zone. This will help you to enter all definitions in step 2 in the proper order. Below is our information neatly written out to greatly assist us and help us keep everything in order: BEFORE YOU START programming your system, you should write down each zone you will have with the proper definition for that zone.The Living Room Motion will be an Interior device that will have a stay/away capabilities in zone 04. We will make the Front Door sensor delayed in zone 01, the Smoke Alarm will be standard 24 hour monitoring in zone 02, the Bedroom Window Sensor we will have Instant arming and disarming in zone 03. Taking the Sample Alarm Kit above and using the common Zone Definitions, here is what we want to do with the system.After entering the Installer Code we will now be in the Programming Section. Every time we are prompted for the installer code we will enter 5555.We will always enter into programming by pressing *8.This will also bypass your motion if you are staying “stay” home.) The motion is bypassed if a delay zone is triggered, giving you the ability to walk in front of the motion to get to a keypad. Here is a list of the most common Zone Definitions:ĭefinition 01 = Delay 1 (ie: door with a certain time of delay)ĭefinition 02 = Delay 2 (ie: door with a different delay time)ĭefinition 03 = Instant (ie: window sensors or doors that do not need a delay)ĭefinition 05 = Interior Stay/Away (This setting is usually for motions. Here is a Sample Alarm Kit we will use for an example : Make sure you’ve got the whole system wired and powered up Press * 5 + Master Code (PROGRAM light will flash) Press * 5 + Master Code (PROGRAM light will flash).Hostage Codes User 33 and 34 (If Programmed) Partition 2 Master Code User 42 (99% of alarms will not use this) Standard Codes User 01 to 32 Master Code (by Default)- 1234 Installer Code (by Default)- 5555 If at anytime you get lost, STOP, and hit #, and then start over. If you get a long beep, the system did not like what you entered. A quick triple beep means the system accepted you entry and is now ready for the next entry. NOTE: If using an LED or PK5501 keypad, you will not see a display or any numbers during your programming. The keypad should beep and then ask you for ‘Section’ again. You will then be asked to enter Installer code. To default the system you will enter into programming mode by typing: Doing so may cause problems in the function of your alarm system.Įven though your system comes factory defaulted we suggest that you default the system just to make sure you have a clean slate to work with. WE DO NOT RECOMMEND BEING IN ANY SECTION OF YOUR SYSTEM UNLESS IT IS ON THIS QUICK START GUIDE.
DSC ALARM PANEL PROGRAMMING SOFTWARE SERIES
